WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property
damage, personal injury, or loss of life.
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For
assistance or additional information
consult a qualified installer, service
agency, or the gas supplier.
Save this manual for future reference.
BLUE FLAME
VENT-FREE PROPANE AND NATURAL
GAS GREENHOUSE CO2 GENERATOR
OWNER’S OPERATION AND INSTALLATION MANUAL
WARNING: This is an unvented gas-
fired appliance. It uses air (oxygen) from
the space in which it is installed. Provi-
sions for adequate combustion and ven-
tilation air must be provided. Refer to
Air for Combustion and Ventilation
sec-
tion on page 3 of this manual.
WARNING: This appliance must not be washed. Use of a pressure washer, water or liquid cleaning
solution on this appliance can cause severe personal injury or property damage due to water and/or
cleaning solution:
In electrical components, connections and wires causing electrical shock or component failure.
On gas control components causing corrosion which can result in gas leaks and fire or explosion
from the leak.
Appliance must be cleaned without being subjected to liquid spray or excessive wetting.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.
This appliance is not for residential use.
DESA International • 2701 Industrial Drive • P.O. Box 90004 • Bowling Green, KY • 42102-9004
RN30E-CAN - Natural Gas
RP30E-CAN - Propane/LP Gas
Vista de pagina 0
1 2 3 4 5 6 ... 17 18

Indice de contenidos

Pagina 1 - BLUE FLAME

®WARNING: If the information in this manual is not followedexactly, a fire or explosion may result causing propertydamage, personal injury, or loss of

Pagina 2 - INFORMATION

10105056BLUE-FLAME VENT-FREE PROPANE/LP ANDNATURAL GAS GREENHOUSE CO2 GENERATOROFFHIGHPILOTLOWIGNITOROPERATING CO2GENERATORFOR YOURSAFETY READBEFORE

Pagina 3

11105056OWNER’S MANUAL1/2 HEAT SHIELDHEIGHTINCORRECT FLAME PATTERNAT HIGH POSITIONINSPECTINGBURNERCheck pilot flame pattern and burner flamepattern of

Pagina 4 - VENTILATION

12105056BLUE-FLAME VENT-FREE PROPANE/LP ANDNATURAL GAS GREENHOUSE CO2 GENERATORTROUBLESHOOTINGNote: All troubleshooting items are listedin order of o

Pagina 5

13105056OWNER’S MANUALTROUBLESHOOTINGContinuedOBSERVED PROBLEMDelayed ignition of burnerBurner backfiring during combustionYellow flame during burner

Pagina 6 - INSTALLATION

14105056BLUE-FLAME VENT-FREE PROPANE/LP ANDNATURAL GAS GREENHOUSE CO2 GENERATORTROUBLESHOOTINGContinuedWARNING ICON G 001 WARNING: If you smell gas• S

Pagina 7

15105056OWNER’S MANUALREPLACEMENTPARTSNote: Use only original replacement parts.This will protect your warranty coverage forparts replaced under warra

Pagina 8

16105056BLUE-FLAME VENT-FREE PROPANE/LP ANDNATURAL GAS GREENHOUSE CO2 GENERATOR124566788910111215171921222320262518141624313ODS/PILOT10-110-2ILLUSTRAT

Pagina 9

17105056OWNER’S MANUALPARTS LISTRP30E-CANRN30E-CANThis list contains replaceable parts used in your appliance. When ordering parts, follow the instruc

Pagina 10 - GENERATOR

KEEP THIS WARRANTYWARRANTY INFORMATIONAlways specify model and serial numbers when communicating with the factory.We reserve the right to amend these

Pagina 11 - 1/2 HEAT SHIELD

2105056BLUE-FLAME VENT-FREE PROPANE/LP ANDNATURAL GAS GREENHOUSE CO2 GENERATORSAFETYINFORMATIONWARNING ICON G 001 WARNINGSIMPORTANT: Read this Owner’s

Pagina 12 - TROUBLESHOOTING

3105056OWNER’S MANUALPRODUCTIDENTIFICATIONFigure 1 - Vent-Free Propane/LP or Natural Gas AppliancePRODUCTFEATURESSafety DeviceThis appliance has a pil

Pagina 13 - OWNER’S MANUAL

4105056BLUE-FLAME VENT-FREE PROPANE/LP ANDNATURAL GAS GREENHOUSE CO2 GENERATORContinued WARNING: If the area in which the CO2 generator may be operate

Pagina 14 - WARNING ICON G 001

5105056OWNER’S MANUALFigure 2 - Ventilation Air From Inside Building If ApplicableOr Remove Door into Adjoining Room, Option 3Ventilation Grills Into

Pagina 15

6105056BLUE-FLAME VENT-FREE PROPANE/LP ANDNATURAL GAS GREENHOUSE CO2 GENERATORINSTALLING APPLIANCE TOWALLMounting BracketThe mounting bracket is locat

Pagina 16 - BREAKDOWN

7105056OWNER’S MANUALINSTALLATIONContinuedMarking Screw Locations1. Tape mounting bracket to wall whereappliance will be located. Make suremounting br

Pagina 17

8105056BLUE-FLAME VENT-FREE PROPANE/LP ANDNATURAL GAS GREENHOUSE CO2 GENERATORFigure 13 - Gas Connection* An A.G.A. or G.G.A. design certified manual

Pagina 18 - 105056 01

9105056OWNER’S MANUALONPOSITIONOFFPOSITIONINSTALLATIONContinuedCHECKING GASCONNECTIONS WARNING: Test all gas pip-ing and connections for leaksafter in

Modelos relacionados RP30E-CAN