Desa FLAME-MAX UNVENTED (VENT-FREE) PROPANE/LP GAS LOG Manual de usuario

Busca en linea o descarga Manual de usuario para Radiadores Desa FLAME-MAX UNVENTED (VENT-FREE) PROPANE/LP GAS LOG . Desa FLAME-MAX UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Save this manual for future reference.
UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
If you cannot reach your gas sup-
plier, call the fire department.
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For
assistance or additional information con-
sult a qualified installer, service agency,
or the gas supplier.
WARNING: This appliance has been spe-
cifically tested and design certified for
installation only in a solid-fuel burning
fireplace, including factory-built UL127
fireplaces and masonry fireplaces, or in
a listed ventless firebox
WARNING: This is an unvented gas-
fired heater. It uses air (oxygen) from
the room in which it is installed. Provi-
sions for adequate combustion and ven-
tilation air must be provided. Refer to
Air for Combustion and Ventilation
sec-
tion on page 3 of this manual.
18" and 24" Variable
Manually-Controlled Models
FLAME-MAX
Vintage Oak
Log Design
OWNER’S OPERATION AND INSTALLATION MANUAL
Models Also Designed Certified as Vented Decorative Appliances
This appliance may be installed in an aftermarket* manufactured (mobile) home, where
not prohibited by state or local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
®
Patent Pending
FLAME-MAX
Golden Oak Log
Design
18", 24", 30, and 36" Variable
Manually-Controlled Model
18", 24", and 30" Variable
Manually-Controlled Model
FLAME-MAX
Birch
Log Design
®
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - PROPANE/LP GAS LOG HEATER

Save this manual for future reference.UNVENTED (VENT-FREE)PROPANE/LP GAS LOG HEATERWARNING: If the information in thismanual is not followed exactly,

Pagina 2

10104256UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX™CONNECTING TO GASSUPPLYNOTICE: A qualified service per-son must connect heater to gassupp

Pagina 3

11104256OWNER’S MANUALINSTALLATIONContinuedThe installer must supply an external regu-lator. The external regulator will reduceincoming gas pressure.

Pagina 4

12104256UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX™ONPOSITIONOFFPOSITIONINSTALLATIONContinuedFigure 15 - Manual Shutoff ValveOpenClosedManua

Pagina 5

13104256OWNER’S MANUALINSTALLATIONContinued WARNING: Failure to posi-tion the parts in accordance withthese diagrams or failure to useonly parts speci

Pagina 6

14104256UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX™1. STOP! Read the safety informationabove.2. Make sure manual shutoff valve isfully open.

Pagina 7

15104256OWNER’S MANUALOPERATINGHEATERContinuedTO TURN OFF GASTO APPLIANCEShutting Off Heater1. Press in and turn control knob clock-wise Clockwise to

Pagina 8

16104256UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX™TROUBLESHOOTINGNote: All troubleshooting items are listedin order of operation. WARNING:

Pagina 9

17104256OWNER’S MANUALTROUBLESHOOTINGContinuedOBSERVED PROBLEMBurner does not light after ODS/pilot is litDelayed ignition burnerBurner backfiring dur

Pagina 10 - VANGUARD FLAME-MAX™

18104256UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX™TROUBLESHOOTINGContinued WARNING: If you smell gas• Shut off gas supply.• Do not try to l

Pagina 11 - OWNER’S MANUAL

19104256OWNER’S MANUALSPECIFICATIONSGolden Oak Golden OakVintage Oak Vintage Oak and Birch and Birch18" Variable 24" Variable 18" Varia

Pagina 12

2104256UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX™SAFETYINFORMATION DANGER: Carbon monoxidepoisoning may lead to death!Carbon Monoxide Poiso

Pagina 13

20104256UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX™ILLUSTRATEDPARTSBREAKDOWNFLAME-MAX™VINTAGE OAK MODELSVYS18P AND VYS24P4123122110112172156

Pagina 14

21104256OWNER’S MANUALPARTS LISTThis list contains replaceable parts used in your heater. When ordering parts, follow theinstructions listed under Rep

Pagina 15

22104256UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX™ILLUSTRATEDPARTSBREAKDOWNFLAME-MAX™ GOLDEN OAKAND BIRCH LOG MODELSVYD18P, VYBD18P, VYD24P

Pagina 16 - OBSERVED PROBLEM

23104256OWNER’S MANUALPARTS LISTThis list contains replaceable parts used in your heater. When ordering parts, follow theinstructions listed under Rep

Pagina 17 - Continued

KEEP THIS WARRANTYWARRANTY INFORMATIONAlways specify model and serial numbers when communicating with the factory.We reserve the right to amend these

Pagina 18

3104256OWNER’S MANUALLOCAL CODESInstall and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The N

Pagina 19 - Parts Under Warranty

4104256UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX™DETERMINING AIR FLOWFOR HEATER LOCATIONDetermining if You Have aConfined or Unconfined Spa

Pagina 20 - ODS Pilot

5104256OWNER’S MANUAL WARNING: If the area in whichthe heater may be operated issmaller than that defined as anunconfined space, provide ad-equate com

Pagina 21

6104256UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX™LOG SIZING REQUIREMENTSLog Minimum FireboxSize Height Depth Front Width18" 17" 1

Pagina 22 - 19 - ODS Pilot

7104256OWNER’S MANUALINSTALLATIONContinuedNOTICE: Manual control heatersmay be used as a vented product.If so, you must always run heaterwith chimney

Pagina 23 - PARTS AVAILABLE — NOT SHOWN

8104256UNVENTED PROPANE/LP GAS LOG HEATERVANGUARD FLAME-MAX™Figure 7 - Minimum Mantel Clearances When Using HoodMinimum Non-Combustible Material 8&quo

Pagina 24 - 104256-01

9104256OWNER’S MANUALINSTALLATIONContinuedINSTALLING DAMPERCLAMP ACCESSORY FORVENTED OPERATIONNote: When used as a vented heater, appli-ance must be i