OWNER’S OPERATION AND INSTALLATION MANUAL
INFRARED VENT-FREE NATURAL GAS HEATER
Models:
CGN10R
and
CGN10RL
Save this manual for future reference.
®
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal
injury, or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by
a qualified installer, service agency, or the
gas supplier.
WARNING: This is an
unvented gas-fired heater.
It uses air (oxygen) from
the room in which it is
installed. Provisions for
adequate combustion
must be provided. Refer to
page 3 of this manual
This appliance may be in-
stalled in an aftermarket*
manufactured (mobile) home,
where not prohibited by state
or local codes.
* Aftermarket: Completion of sale,
not for purpose of resale, from the
manufacturer
This appliance is only for use
with the type of gas indicated
on the rating plate. This appli-
ance is not convertible for
use with other gases.
Vista de pagina 0
1 2 3 4 5 6 ... 19 20

Indice de contenidos

Pagina 1

OWNER’S OPERATION AND INSTALLATION MANUALINFRARED VENT-FREE NATURAL GAS HEATERModels:CGN10RandCGN10RLSave this manual for future reference.®WARNING: I

Pagina 2

10103549GAS RESIDENTIAL HEATERSTO SELECTHEATING LEVELPilot BurnerThermocoupleFigure 16 - Pilot7. Keep control knob pressed in for 10seconds after ligh

Pagina 3

11103549OWNER’S MANUALControlKnobs BurnersLOWOFFPILOTHIGHOFFPILOTOFFFigure 17 - Burner PatternsOPERATINGHEATERContinuedTO TURN OFF GASTO APPLIANCEShut

Pagina 4

12103549GAS RESIDENTIAL HEATERSTROUBLESHOOTINGNote: All Trouble Shooting items are listedin order of operation. WARNING: Turn off heater and let cool

Pagina 5

13103549OWNER’S MANUALREMEDY1. Press in control knob fully2. After ODS/pilot lights, keep controlknob pressed in 10 seconds3. Fully open manual shut-o

Pagina 6

14103549GAS RESIDENTIAL HEATERSWhen gas pressure is too low• pilot will not stay lit• burner(s) will have delayed ignition• heater will not produce sp

Pagina 7

15103549OWNER’S MANUALCLEANING ANDMAINTENANCE WARNING: Turn off heaterand let cool before cleaning. CAUTION: You must keepcontrol areas, burner, and c

Pagina 8

16103549GAS RESIDENTIAL HEATERS23GRH VP11AGRH VP11A2120191817141516131012991122786654321AB232425GRH VP11AGRH VP11AGRHpv013.U 257-17-2ILLUSTRATEDP

Pagina 9 - POSITION

17103549OWNER’S MANUALPARTS LISTCGN10RCGN10RLThis list contains replaceable parts used in your heater. When ordering parts, follow the instructionslis

Pagina 10 - GAS RESIDENTIAL HEATERS

18103549GAS RESIDENTIAL HEATERSNOTES__________________________________________________________________________________________________________________

Pagina 11 - OWNER’S MANUAL

19103549OWNER’S MANUALNOTES___________________________________________________________________________________________________________________________

Pagina 12

2103549GAS RESIDENTIAL HEATERSSAFETYINFORMATION WARNINGSIMPORTANT: Read this owner’smanual carefully and completelybefore trying to assemble, oper-a

Pagina 13

KEEP THIS WARRANTYWARRANTY INFORMATION103549-01REV. A03/972701 Industrial DriveP.O. Box 90004Bowling Green, KY 42102-9004DESA International warrants t

Pagina 14

3103549OWNER’S MANUALHeaterCabinetGrillGuardBurnersFrontPanelFigure 1 - Vent-Free Natural Gas HeaterControl KnobPiezo Ignitor ButtonPRODUCTIDENTIFICAT

Pagina 15

4103549GAS RESIDENTIAL HEATERSDETERMINING AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Confined or Unconfined SpaceUse this worksheet to dete

Pagina 16

5103549OWNER’S MANUALOr Remove Door into Adjoining Room, Option 3Ventilation Grills Into Adjoining Room,Option 212"12"VentilationGrillsinto

Pagina 17

6103549GAS RESIDENTIAL HEATERS36"3"FLOORCEILINGMinimumMinimum To Top Surface Of Carpeting, Tile Or OtherCombustible Material8"MinimumFr

Pagina 18

7103549OWNER’S MANUALMountingScrewLocations10 7/8"Minimum ToMaintain 6"ClearanceFrom Wall7 3/4"20 1/4"Minimum ToMaintain 3"Cl

Pagina 19

8103549GAS RESIDENTIAL HEATERSManualShutoff Valve *Figure 12 - Gas Connection* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap

Pagina 20 - WARRANTY INFORMATION

9103549OWNER’S MANUALONPOSITIONOFFPOSITIONCHECKING GASCONNECTIONSPRESSURE TESTINGHEATER GASCONNECTIONS1. Open manual shutoff valve (see Figure13).2. O